The T34™ is the safety standard in ambulatory syringe pumps – offering a comprehensive range of features designed to maximise safe and simple administration of medication, in both hospital and homecare environments.

Key Features

  • Lightweight, compact and fully ambulatory
  • Powered by a 9V (6LR61) type battery
  • Three point syringe detection feature, each with displacement alarm
  • Volume detection and automatic calculation of infusion rate and volume detected in ml/hr
  • Code protected programmes that are configured and locked into the pump memory and can only be accessed by authorised personnel or technicians
Log In / Register To Buy Online

Main Features

  • Lightweight, compact and fully ambulatory
  • Powered by a 9V (6LR61) type battery
  • Syringe recognition of commonly used syringe brands (2 to 50ml)
  • Three point syringe detection feature, each with displacement alarm
  • Volume detection and automatic calculation of infusion rate in ml/hr

Safety Features

  • Code protected programmes that are configured and locked into the pump memory and can only be accessed by authorised personnel or technicians
  • Current infusion history can be viewed during infusion
  • Pump event log accessible via INFO MENU or downloaded to PC through BodyComm software
  • Comprehensive range of alerts / alarms with descriptive display of state and resolution
  • The lockable keypad prevents inadvertent key presses

Consumables

  • Please contact a member of our Customer Support Team on 01253 206700 for more information about administration sets for the T34

Technical Specification

Device type Syringe pump with motor driven linear actuator, pulsed motion
Flow rate 0.05 to 10ml/h in 0.1ml increments, 10 to 650ml/h in 1 ml increments
Actuator stoke c 67mm available
Syringe sizes 2ml to 50ml (pump configured to most commonly used syringes including, Monoject, Braun, Terumo and Codan syringes but can also be programmed to other brands)
Pump accuracy +/- 5% system accuracy (pump and set combined)
Occlusion pressure 100 to 1500mmHg configurable (10mmHg increments) Max. actuator force 50N (5Kgf)
Battery 9V alkaline, IEC 6LR61 or 6LF22 type
Battery operation 7 full deliveries depending on infusion and set up parameters
Indicators Four line LCD display (122 x 32 pixels) and dual colour operation LED
Alarms and Alerts When a problem is detected, the T34TM displays the following alarm messages, sounds an audible alarm and the red LED lights - occlusion or syringe empty, pump paused too long, end program, syringe displaced, end battery, syringe empty
T34 dimensions 169 x 53 x 23mm
Classification Type CF Equipment, degree of protection against electrical shock Class II equipment, IPX3 protection against ingress of water
Housing ABS (fire retardant)
Weight 210g (without battery), 274g (with battery)
Electrical safety Complies with EN 60601-1 (Medical Electrical Equipment Safety) IEC 60601-2-24 (Infusion Pumps and Controllers) IEC 60601-1-4 (Programmable Electrical Medical System) UL 2601-1 and CAN/CSA C22.2 no 601.1
Standards Manufactured in accordance with ISO 9001;2008 and ISO 13485;2003. CE marked (in accordance with the Medical Devices Directive 93/42/EEC)
EMC in compliance with EN 60601-1 (safety) and IEC 60601-2-24 (EMC)
Environmental Specifications Non Operating Conditions (transportation and storage)
Temperature -25°C to +55°C (-13°F to +131°F)
Humidity 5% to 100% R.H., non-condensing
Air pressure 48kPa to 110kPa
Operating Conditions The system may not meet all performance specifications if operated outside of the following conditions
Temperature 0°C to +45°C (+59°F to +113°F)
Humidity 20% to 85% R.H. at +40°C, non-condensing
Air pressure 70kPa to 110kPa