T60™ Ambulatory Syringe Pump

The T60™ ambulatory syringe pump accommodates 2 to 60ml syringes – with a rechargeable li-polymer battery offering a comprehensive range of features designed to maximise safe and simple administration of medication in both hospital and homecare environments.

Key Features

  • Rechargeable Li-Polymer battery and pole mounted mains charger allow greater flexibility
  • Lightweight and compact
  • Pole mounted or ambulatory
  • Three point syringe detection feature, each with displacement alarm
  • Code protected clinician bolus function
  • Volume detection and automatic calculation of infusion rate in ml/hr

Request More Information

Main Features

  • Integral protective syringe cover
  • Lightweight and compact
  • Pole mounted or ambulatory
  • Three point syringe detection feature, each with displacement alarm
  • Syringe recognition of commonly used syringe brands (2 to 60ml)
  • Code protected clinician bolus function
  • Rechargeable Li-Polymer battery and pole mounted mains charger allow greater flexibility
  • Volume detection and automatic calculation of infusion rate in ml/hr
  • Automatic bolus rate adjustment optimises bolus delivery and prevents false occlusion alarms

Safety Features

  • Code protected programmes that are configured and locked into the pump memory and can only be accessed by authorised personnel or technicians
  • Current infusion history can be viewed during infusion
  • Pump event log accessible via INFO MENU or downloaded to PC through BodyComm software
  • Comprehensive range of alerts / alarms with descriptive display of state and resolution
  • Lockable keypad to prevent inadvertent key activation
  • Alarmed syringe sensors to detect syringe displacement
  • Configurable occlusion pressures for different clinical applications or therapy

Accessories

  • 100-174SL: T60/TPCA/T34 50ml Lockbox + 2 Keys
  • 100-176SD: T34/T60 Single Use Carry Pouch
  • 100-178S: Large Washable Carry Pouch
  • 100-099SLA: Dongle, IR220, RS232 Fixed Baud Rate
  • 150-311CPC: Docking Station RS232 Lead
  • USB2: USB Serial Adapter
  • 151-132X: UK Wall Charger -8.2V
  • 400-651SL: T60 Pole Mounting Device
  • BODYCOMM1: Bodycomm TPCA/T60 - No Leads
  • BODYCOMM2: Bodycomm TPCA/T60 - With RS232 Lead
  • BODYCOMM3: Bodycomm TPCA/T60 - With USB Adapter
  • BCS93: Bodycomm 93 Software

Consumables

  • Please contact a member of our Customer Support Team on 01253 206700 for more information about administration sets for the T60.

Technical Specification

Type Syringe pump with motor driven linear actuator, pulsed motion (560 pulses per mm)
Flow rate 0.05-10ml/h in 0.01ml increments, 10 to 650ml/h in 1 ml increments
Actuator travel c 106 mm available
Syringe sizes 2ml to 50/60ml (pump configured to most commonly used syringes including, BD Plastipak, Monoject, Braun, Terumo and Codan syringes but can also be programmed to other brands)
Accuracy +/- 5% system accuracy (pump and set combined)
Occlusion pressure 100-1500mmHg configurable (10mmHg increments) Max. actuator force 50N (5Kgf)
Battery Integral rechargeable li-Polymer 1800 mAh
Battery operation c.100 full deliveries depending on infusion and set up parameters
Indicators 4 line LCD display (128x64 pixels), dual colour operation LED with backlight
Alarms and alerts When a problem is detected, the T60™ displays the following alarm messages, sounds an audible alarm and the LED lights red - pump paused too long, occlusion or syringe empty, end program, end battery, syringe displaced, syringe empty
T60TM dimensions 38 x 55 x 190mm
Classification Type CF equipment, degree of protection against electrical shock Class II equipment. IPX1 protection against ingress of water
Housing ABS (fire retardant)
Weight 400g with battery
Electrical safety Complies with EIC 60601-1 (Medical Electrical Equipment Safety), IEC 60601-2-24 (Infusion Pumps and Controllers), IEC 601-1-4 (Programmable Electrical Medical Systems)
Standards Manufactured in accordance with ISO 9001;2008 and ISO 13485;2003. CE marked (in accordance with the Medical Devices Directive 93/42/EEC)
EMC the T60TM is designed to be in compliance with EN 60601-1 (safety) and IEC 601-1-2 (EMC)
Environmental specifications Non operating conditions (transportation and storage)
Temperature -25°C to 50°C (-13°F to +131°F)
Humidity 5% to 100% R.H., non-condensing
Air pressure 48kPa to 110kPa
Operating conditions The system may not meet all performance specifications if operated outside of the following conditions
Temperature +15°C to +45°C (+59°F to +113°F)
Humidity 20% to 85% R.H. at +40°C, non-condensing
Air pressure 70kPa to 110kPa